Independent Carbon Monoxide Alarm Manufacturer (PA-003W)

Listing Date: 2017-04-14

50ppm: the maximum concentration that healthy adults can withstand within eight hours;
200ppm: slight headache after 2-3 hours;
400ppm: forehead pain within 1-2 hours: life-threatening after 3 hours;
800ppm: after 45 minutes, dazzling, nausea, cramps: loss of consciousness after 2 hours;
1600ppm: headache, dizziness, nausea within 20 minutes: death within 1 hour;
3200ppm: headache, dazzling, nausea within 5-10 minutes: death within 25-30 minutes;
6400ppm: headache, dazzling, nausea within 1-2 minutes: death within 10-15 minutes;
12800ppm: death within 1-3 minutes;


50ppm: Maximum concentration that healthy adults can tolerate in eight hours

200ppm: slight headache after 2-3 hours

400ppm: Forehead pain within 1-2 hours: Life threatening after 3 hours

800ppm: 45 minutes, dazzling, nausea, cramps: loss of consciousness after 2 hours

1600ppm: headache, dizziness, nausea within 20 minutes: death within 1 hour

3200ppm: headache, dizziness, nausea within 5-10 minutes: death within 25-30 minutes

6400ppm: headache, dizziness, nausea within 1-2 minutes: death within 10-15 minutes

12800ppm: death within 1-3 minutes


Note: The symptoms of CO poisoning in the table above are for healthy adults and for high-risk and vulnerable people. Its response is different. Staying in a carbon monoxide environment containing a concentration of 50 ppm for more than eight hours may also cause carbon monoxide poisoning. The electrochemical carbon monoxide detector is dedicated to the detection of CO gas. CO gas is a colorless, odorless, non-irritating, toxic gas that cannot be sensed by the senses. It is mostly generated in the combustion environment of fireplaces, wood, coal, electric heaters and water heaters that lack oxygen.


Therefore, in order to ensure the safety of home life, it is recommended to install carbon monoxide alarm detectors in kitchens, bathrooms, living rooms, bedrooms, garages and other places where there is no air circulation for a long time. The product is powered by a DC 9V battery. When the detector alarms, it will give an alarm sound of ≥85dB, and the red alarm light will flash at the same time. During normal operation, the green indicator flashes once every 30 seconds. The detector has a low voltage alarm function and a key test function. Press the test button on the panel for 1 second to sound an alarm and the red indicator light will flash. The detector uses low power consumption technology, and the theoretical battery is replaced once a year. Sensor fault detection function: yellow LED flashes and buzzer is displayed at the same time-(fault can be automatically restored).


Technical Parameters:


> Working voltage: 9V battery

> Static current: ≤15 ~ 35uA

> Alarm current: ≤10 ~ 30mA

> Alarm concentration:

When the concentration is 30ppm, the alarm will alarm within 120 minutes;

When the concentration is 50ppm, the alarm will alarm within 60-90 minutes;

When the concentration is 100ppm, the alarm will alarm within 10-40 minutes;

When the concentration is 300ppm, the alarm will alarm in 3 minutes

更准确、更可靠、重复性好 > Sensor: Adopts innovative imported electrochemical carbon monoxide sensor, which is more accurate, reliable and repeatable.

> Real-time LCD display function, sensor fault detection function (yellow LED display)

> Alarm loudness: ≥85dB (3m)


file format:
File size: 750KB
Updated: - 04 - 05 2017-04-05
Hot Products / Related Products
独立一氧化碳探测器报警器(PA-001W)
- 04 - 14 2017-04-14
50ppm: Maximum concentration that healthy adults can withstand within eight hours; 200ppm: slight headache after 2-3 hours; 400ppm: forehead pain within 1-2 hours: life-threatening after 3 hours; 800ppm: after 45 minutes Nausea, convulsions: loss of consciousness after 2 hours; 1600ppm: headache, dazzle, nausea within 20 minutes: death within 1 hour; 3200ppm: headache, dazzle, nausea within 5-10 minutes: death within 25-30 minutes; 6400ppm: 1- Headache, dazzling, nausea within 2 minutes: death within 10-15 minutes; 12 ...
有线燃气报警器(PA-205)
- 04 - 14 2017-04-14
The gas alarm is a gas leak detection alarm. When the gas leaks in the environment and the gas alarm detects that the gas concentration reaches the critical point set by the explosion or poison alarm, the gas alarm will send out an alarm signal. This product is suitable for places where natural gas exists. Fire, explosion, poisoning and other accidents can be detected and alarmed. The product has the characteristics of high sensitivity, high stability, all kinds of detection gas, and small size.
无线门磁感应器门磁报警器(PB-62)
- 03 - 30 2017-03-30
The door magnet is composed of a wireless transmission module and a magnetic block. There are two components of a "steel spring tube" at the two arrows of the wireless transmission module. When the distance between the magnet and the steel spring tube is kept within 1.5 cm, The steel spring tube is in the disconnected state. Once the distance between the magnet and the steel spring tube exceeds 1.5 cm, the steel spring tube will be closed, causing a short circuit, and the alarm indicator will be turned on while the alarm signal is transmitted to the host.
有线幕帘红外探测器(PA-82D )
- 03 - 29 2017-03-29
Microprocessor-controlled low-voltage alarm function is used in all-round automatic temperature compensation SMT process manufacturing, anti-RFI, EMI interference dynamic threshold adjustment technology, effectively prevents interference. Three-level pulse count can be adjusted, which is convenient for use in different environments.