product name:

Domestic gas detection alarm (PA-213)

Listing Date: 2018-05-31

After the installation of the gas leak detector, you can use a lighter to ignite and release a small amount of gas at a position about 5CM from the gas convection window to detect the alarm condition of the detector. Due to the inherent characteristics of the sensor, please do not release too much. Concentrated gas is used to test the detector. Do not test the detector frequently for a long time. This may damage the gas-sensitive material of the sensor, reduce the sensitivity of the detector, and damage the detector.

Working voltage: AC220V ± 15%, 50HZ

Power consumption: standby ≤3W, alarm ≤6W

Alarm concentration: 6% LEL

Alarm sound intensity: ≥70dB (1 meter directly in front)

Working environment: 0 ℃ ~ + 55 ℃, relative humidity <95% RH

Stability: Long-term working alarm concentration error is not greater than ± 5% LEL

Repeatability: Repeated test alarm concentration error is not greater than ± 3% LEL

Alarm concentration error: ± 3% LEL

Alarm mode: audible and visual alarm; linkage solenoid valve output (optional); normally open / normally closed output (optional)

Sampling method: natural diffusion

Detection gas: natural gas (CH4)

Executive standard: GB 15322.2-2003 [Combustible gas detectors Part 2: Standard requirements for independent combustible gas detectors with a measuring range of 0 to 100% TEL

Dimensions: 122 * 68 * 30MM

Weight: 150 grams


Working voltage: AC220V ± 15%, 50HZ

Power consumption: standby ≤3W, alarm ≤6W

Alarm concentration: 6% LEL

Alarm sound intensity: ≥70dB (1 meter directly in front)

Working environment: 0 ℃ ~ + 55 ℃, relative humidity <95% RH

Stability: Long-term working alarm concentration error is not greater than ± 5% LEL

Repeatability: Repeated test alarm concentration error is not greater than ± 3% LEL

Alarm concentration error: ± 3% LEL

Alarm mode: audible and visual alarm; linkage solenoid valve output (optional); normally open / normally closed output (optional)

Sampling method: natural diffusion

Detection gas: natural gas (CH4)

Executive standard: GB 15322.2-2003 [Combustible gas detectors Part 2: Standard requirements for independent combustible gas detectors with a measuring range of 0 to 100% TEL]

Dimensions: 122 * 68 * 30MM

Weight: 150 grams


Hot Products / Related Products
独立一氧化碳探测器报警器(PA-001W)
- 04 - 14 2017-04-14
50ppm: the maximum concentration that healthy adults can withstand within eight hours; 200ppm: slight headache after 2-3 hours; 400ppm: forehead pain within 1-2 hours: life-threatening after 3 hours; 800ppm: after 45 minutes, dazzling, Nausea, cramps: Loss of consciousness after 2 hours; 1600ppm: headache, dazzle, nausea within 20 minutes: death within 1 hour; 3200ppm: headache, dazzle, nausea within 5-10 minutes: death within 25-30 minutes; 6400ppm: Headache, dazzling, nausea within 2 minutes: death within 10-15 minutes; 12 ...
有线燃气报警器(PA-205)
- 04 - 14 2017-04-14
The gas alarm is a gas leak detection alarm. When the gas leaks in the environment and the gas alarm detects that the gas concentration reaches the critical point set by the explosion or poison alarm, the gas alarm will send out an alarm signal. This product is suitable for places where natural gas exists. Fire, explosion, poisoning and other accidents can be detected and alarmed. The product has the characteristics of high sensitivity, high stability, all kinds of detection gas, and small size.
无线门磁感应器门磁报警器(PB-62)
- 03 - 30 2017-03-30
The door magnet is composed of a wireless transmission module and a magnetic block. There are two components of a "steel spring tube" at the two arrows of the wireless transmission module. When the distance between the magnet and the steel spring tube is kept within 1.5 cm, The steel spring tube is in the disconnected state. Once the distance between the magnet and the steel spring tube exceeds 1.5 cm, the steel spring tube will be closed, causing a short circuit, and the alarm indicator will be turned on while the alarm signal is transmitted to the host.
有线幕帘红外探测器(PA-82D )
- 03 - 29 2017-03-29
Microprocessor-controlled low-voltage alarm function is used in all-round automatic temperature compensation SMT process manufacturing, anti-RFI, EMI interference dynamic threshold adjustment technology, effectively prevents interference. Three-level pulse counting can be adjusted, which is convenient for different environments







Copyright © 2005-2013 Shenzhen Pilot Guards Security Technology Co., Ltd.
Global marketing network Bottom picture
X
5

Phone number management

  • 0755-33252178
1

QQ settings

3

SKYPE settings

4

Ali Wangwang Settings

6

QR code management

Back to top
Expand
七乐彩 欢乐拼三张 欢乐拼三张 星力捕鱼